KSL, KSLT
and KSG have been used sucessfully for many years and
were permanently improved and adapted to the latest
stage of technology. They are conductor lines in a rigid PVC
housing, suitable for indoor and outdoor (preferably
KSLT & KSG) installations. The systems fully meet international safety
standards (VDE 0470 §3) and are available in 4 and 5 conductor
versions. They particularly suit for
mobile power feeding of overhead cranes, monorail systems, hoists,
automated storage and retrieval
systems, power tools, machine tools, assembly and test lines and
many other applications. The
Powerails require a minimum of space, are easy to install and do not
corrode. Standard lengths are 1 / 2 / 3 / 4 m plus specific lengths and curves as required.
Cat. 4a
|
![]() |
Powerail VKS is
a space saving conductor system, designed to prevent accidental
touch to regulations VDE 0470
part 1 (EN 60529). It consists of a flat PVC housing and pure copper
or stainless steel conductors. The minimum space required allows the
system to be integrated in the crane or hoist track.
Multipole systems with 3 - 6 conductors are available and several
housings can be easily combined
to get as many conductors as required. VKS can be used for indoor
and roof-over (rain-protected) applications. The system is
designed for hoists, stacker cranes, monorails, machine tools,
testing lines and many other types of mobile equipment. The PVC
housing holds 3 - 6 conductors for power supply and control
functions. Standard lengths are 4 m, plus specific lengths as
required.
Cat. 4b
|
![]() |
MKL is a
totally enclosed conductor system with 6 - 8 conductors, for indoor
and outdoor use. The gray coloured housing
can be supplied with different copper sections for ratings from
40 - 200 Amp. After installation of the PVC housing the flat copper bars, supplied in
coils, are to be pulled into the housing, using factory-supplied
tools. MKL requires a minimum of space, is easy to install and
cannot corrode. Typical applications are overhead cranes, monorails,
hoists, storage and retrieval systems, power tools, lighting systems
and many others.
Cat. 4c |
Profile | Type | Number of Conductors |
Ampacity [A] at 100 % ED / 35° C |
Max. Voltage [V] |
---|---|---|---|---|
![]() |
KSL | 4 - 5 | 60 - 200* | 600 |
![]() |
KSG | 4 - 5 | 120 - 200 | 600 |
![]() |
VKS | 3 - 6 | 10 - 120 | 600 |
![]() |
MKL | 6 - 8 | 40 - 200** | 600 |
All Powerails are designed to meet relevant electrical, mechanical and fire-preventing regulations. Due to their worldwide use, most systems are approved by UL, CSA and SEV.